BS EN 15714-3-2009 工业阀门.执行器.第3部分:工业阀门用部分回转气压执行器.基本要求.pdf
BS EN 15714-32009 ICS 23.060.20 NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAW BRITISH STANDARD Industrial valves Actuators Part 3 Pneumatic part-turn actuators for industrial valves Basic requirements This British Standard was published under the authority of the Standards Policy and Strategy Committee on 30 November 2009 BSI 2009 ISBN 978 0 580 54843 7 Amendments/corrigenda issued since publication DateComments BS EN 15714-32009 National foreword This British Standard is the UK implementation of EN 15714-32009. The UK participation in its preparation was entrusted to Technical Committee PSE/18/5, Valve actuators. A list of organizations represented on this committee can be obtained on request to its secretary. This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. Compliance with a British Standard cannot confer immunity from legal obligations. 标准分享网 w w w .b z f x w .c o m 免费下载 w w w . b z f x w . c o m BS EN 15714-32009 EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 15714-3 October 2009 ICS 23.060.20 English Version Industrial valves - Actuators - Part 3 Pneumatic part-turn actuators for industrial valves - Basic requirements Robinetterie industrielle - Actionneurs - Partie 3 Actionneurs pneumatiques fraction de tour pour robinetterie industrielle - Prescriptions de base Industriearmaturen - Antriebe - Teil 3 Pneumatische Schwenkantriebe fr Industriearmaturen - Grundanforderungen This European Standard was approved by CEN on 12 September 2009. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN Management Centre or to any CEN member. This European Standard exists in three official versions English, French, German. A version in any other language made by translation under the respons bility of a CEN member into its own language and notified to the CEN Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre Avenue Marnix 17, B-1000 Brussels 2009 CEN All rights of exploitation in any and by any means reserved worldwide for CEN national Members. Ref. No. EN 15714-32009 E w w w . b z f x w . c o m BS EN 15714-32009 EN 15714-32009 E 2 Contents Page Foreword ..............................................................................................................................................................4 1 Scope ......................................................................................................................................................5 2 Normative references ............................................................................................................................5 3 Classification/Designation ....................................................................................................................5 3.1 General ....................................................................................................................................................5 3.2 Action ......................................................................................................................................................5 3.3 Actuator attachment ..............................................................................................................................5 3.4 Perance data...................................................................................................................................6 3.4.1 Output torques .......................................................................................................................................6 3.4.2 Minimum moving pressure ...................................................................................................................6 3.4.3 Operating time ........................................................................................................................................6 3.4.4 Air volume ..............................................................................................................................................6 3.4.5 Motive energy .........................................................................................................................................6 4 Design requirements .............................................................................................................................6 4.1 Endurance of part-turn actuators .........................................................................................................6 4.2 Leakage ...................................................................................................................................................7 4.3 Angle for part-turn actuators ................................................................................................................7 4.4 Environmental conditions .....................................................................................................................7 4.4.1 Ambient temperature .............................................................................................................................7 4.4.2 Enclosure protection .............................................................................................................................8 4.4.3 Corrosion protection .............................................................................................................................8 4.5 Basic design ...........................................................................................................................................8 4.5.1 Safety requirements ..............................................................................................................................8 4.5.2 Part-turn actuator attachment ..............................................................................................................9 4.5.3 Pressure connections and pilot valves interface ...............................................................................9 4.5.4 Fail safe direction for spring return actuators ................................................................................. 11 4.5.5 Mechanical safety factors .................................................................................................................. 11 4.5.6 Position indication .............................................................................................................................. 11 4.6 Optional equipment ............................................................................................................................ 11 4.6.1 Ancillaries ............................................................................................................................................ 11 4.6.2 Manual operation ................................................................................................................................ 13 4.6.3 End stop adjustment for part-turn actuators ................................................................................... 14 5 Conity assessment ..................................................................................................................... 14 5.1 General ................................................................................................................................................. 14 5.2 Type tests ............................................................................................................................................ 14 5.3 Control of production process and quality system ........................................................................ 14 6 Marking ................................................................................................................................................ 15 6.1 General requirements on marking .................................................................................................... 15 7 Part-turn actuator selection guidelines ............................................................................................ 16 8 Documentation .................................................................................................................................... 16 Annex A normative Endurance test procedure .......................................................................................... 17 A.1 General ................................................................................................................................................. 17 A.2 Test equipment ................................................................................................................................... 17 A.3 Test conditions ................................................................................................................................... 17 A.4 Test procedure .................................................................................................................................... 17 A.5 Acceptance criteria ............................................................................................................................. 17 Annex B inative Actuator selection guidelines ................................................................................... 19 标准分享网 w w w .b z f x w .c o m 免费下载 w w w . b z f x w . c o m BS EN 15714-32009 EN 15714-32009 E 3 B.1 General ................................................................................................................................................. 19 B.2 Selection parameters .......................................................................................................................... 19 B.3 Actuator selection ............................................................................................................................... 20 B.3.1 General ................................................................................................................................................. 20 B.3.2 Torque characteristics for rack and pinion or vane actuators ....................................................... 21 B.3.3 Torque characteristics for scotch yoke actuators e.g. symmetric system ................................. 22 Bibliography ...................................................................................................................................................... 23 w w w . b z f x w . c o m BS EN 15714-32009 EN 15714-32009 E 4 Foreword This document EN 15714-32009 has been prepared by Technical Committee CEN/TC 69 “Industrial valves”, the secretariat of which is held by AFNOR. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by April 2010, and conflicting national standards shall be withdrawn at the latest by April 2010. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent rights. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. 标准分享网 w w w .b z f x w .c o m 免费下载 w w w . b z f x w . c o m BS EN 15714-32009 EN 15714-32009 E 5 1 Scope This document provides basic requirements for pneumatic part-turn valve actuators, both double acting and single acting, used for on-off and modulating control duties. It includes guidelines, recommendations and s for enclosure and corrosion protection, control and testing. It does not apply to pneumatic actuators which are integral parts of control valves. Other requirements, or conditions of use, different from those indicated in this document, should be subject to negotiations, between the purchaser and the manufacturer/supplier, prior to order. The terms and definitions applicable to this European Standard are given in EN 15714-1. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document including any amendments applies. EN 12570, Industrial valves for sizing the operating element EN 60529, Degrees of protection provided by enclosures IP Code IEC 605291989 EN ISO 228-1, Pipe threads where pressure-tight joints are not made on the threads Part 1 Dimensions, tolerances and designation ISO 228-12000 EN ISO 5211, Industrial valves Part-turn valve actuator attachments ISO 52112001 EN ISO 9227, Corrosion tests in artificial atmospheres Salt spray tests ISO 92272006 ISO 5599-2, Pneumatic fluid power Five-port directional control valves Part 2 Mounting interface surfaces with optional electrical connector ASME B1.20.11983, Pipe Threads, General Purpose Inch 3 Classification/Designation 3.1 General Part-turn valve actuators are classified by action and interface as detailed below. 3.2 Action a Double Acting DA b Single Acting SA with spring action to move clock-wise CW or counter clock-wise CCW, as per 4.5.4 3.3 Actuator attachment As per EN ISO 5211. w w w . b z f x w . c o m BS EN 15714-32009 EN 15714-32009 E 6 3.4 Perance data 3.4.1 Output torques The guaranteed minimum output torque capability of the actuator, in both directions, at specified supply pressures shall be provided by the manufacturer/supplier. Where the output torque varies with the stroke, in a non-linear relationship, tabulated data and/or torque/stroke curves shall be provided. 3.4.2 Minimum moving pressure The actuator minimum moving pressure for double acting ac