BS EN 12259-3-2000 固定灭火系统 水喷淋和水雾系统部件 第3部分 报警干阀组件.pdf
BRITISH STANDARD BS EN 12259-32000 Incorporating Amendments Nos. 1 and 2 and Corrigendum No. 1 Fixed firefighting systems Components for sprinkler and water spray systems Part 3 Dry alarm valve assemblies The European Standard EN 12259-32000, with the incorporation of Amendments A12001 and A22005, has the status of a British Standard ICS 13.220.20 Licensed Copy London South Bank University, London South Bank University, Thu Aug 10 125728 BST 2006, Uncontrolled Copy, c BSI BS EN 12259-32000 This British Standard, having been prepared under the direction of the Health and Environment Sector Policy and Strategy Committee, was published under the authority of the Standards Policy and Strategy Committee on 15 August 2000 BSI 2006 ISBN 0 580 34113 5 National foreword This British Standard is the official English language version of EN 12259-32000, including amendments A12001 and A22005. This European Standard is the subject to transitional arrangements agreed under a Commission mandate which is intended to lead to CE marking in support of the Construction Products Directive. In order to allow for any changes in national regulations, the Member States have agreed a transition period. The UK participation in its preparation was entrusted by Technical Committee FSH/18, Fixed firefighting systems, to Subcommittee FSH/18/2, Sprinklers, which has the responsibility to A list of organizations represented on this subcommittee can be obtained on request to its secretary. Cross-references The British Standards which implement international or European publications referred to in this document may be found in the BSI Catalogue under the section entitled “International Standards Correspondence Index”, or by using the “Search” facility of the BSI Electronic Catalogue or of British Standards Online. This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. aid enquirers to understand the text; present to the responsible international/European committee any enquiries on the interpretation, or proposals for change, and keep UK interests ined; monitor related international and European developments and promulgate them in the UK. Summary of pages This document comprises a front cover, an inside front cover, the EN title page, pages 2 to 54, an inside back cover and a back cover. The BSI copyright date displayed in this document indicates when the document was last issued. Sidelining in this document indicates the most recent changes by amendment. Amendments issued since publication Amd. No. DateComments 1202321 December 2001 13882 Corrigendum No. 1 24 October 2002Revision of national foreword 1635830 June 2006Indicated by a sideline Licensed Copy London South Bank University, London South Bank University, Thu Aug 10 125728 BST 2006, Uncontrolled Copy, c BSI EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 12259-3 May 2000 A1 A2 February 2001 November 2005 ICS 13.220.20; 13.320 English version Fixed firefighting systems – Components for sprinkler and water spray systems – Part 3 Dry alarm valve assemblies includes amendments A12001 and A22005 Sytmes fixes de lutte contre l’incendie – Composants des systmes sprinkleurs et pulvrisation d’eau – Partie 3 Postes d’alarme sous air inclut les amendements A12001 et A22005 Ortsfeste Lschanlagen – Bauteile fr Sprinkler- und Sprhwasseranlagen – Teil 3 Trockenalarmventile und Zubehr enthlt nderungen A12001 und A22005 This European Standard was approved by CEN on 17 December 1999. Amendment A12001 was approved by CEN on 20 January 2001 and amendment A22005 was approved by CEN on 19 October 2005. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CEN member. This European Standard exists in three official versions English, French, German. A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the Central Secretariat has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Central Secretariat rue de Stassart, 36 B-1050 Brussels 2000 CEN All rights of exploitation in any and by any means reserved worldwide for CEN national Members. Ref. No. EN 12259-32000 A12001 A22005 E Licensed Copy London South Bank University, London South Bank University, Thu Aug 10 125728 BST 2006, Uncontrolled Copy, c BSI Page 2 EN 12259-32000 BSI 2006 Contents Page Foreword 3 1 Scope 7 2 Normative references 7 3 Definitions 8 4 Dry alarm valve assembly construction and perance 11 5 Quick opening device construction and perance 19 6 Marking 22 7 Instructions for installation and operation 24 8 Conditions for testing 25 9 uation of conity 25 Annex A normative Fire exposure test for body and cover 26 Annex B normative Strength test for body and cover 29 Annex C normative Flow tests for dry alarm valves 30 Annex D normative Sealing assembly tests 33 Annex E normative Perance tests 37 Annex F normative Resistance to ageing test for non-metallic components excluding gaskets and seals 41 Annex G normative Leakage resistance test 43 Annex H normative Test for sealing assembly elements resistance to adhesion 44 Annex I normative Endurance test 45 Annex J normative Installation pressure leak resistance test 46 Annex K normative Strength and leak resistance test 47 Annex L inative Typical testing schedule and example of test specimen numbers for dry alarm valve 48 Annex M normative Salt mist corrosion test 49 Annex ZA inative Clauses of this European Standard addressing the provisions of the EU Construction Products Directive 50 Bibliography 54 Licensed Copy London South Bank University, London South Bank University, Thu Aug 10 125728 BST 2006, Uncontrolled Copy, c BSI Page 3 EN 12259-32000 BSI 2006 Foreword This European Standard has been prepared by Technical Committee CEN/TC 191, Fixed fire fighting systems, the Secretariat of which is held by BSI. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by November 2000, and conflicting national standards shall be withdrawn at the latest by November 2000. This European Standard has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association, and supports essential requirements of EU Directives. It s one part of EN 12259, covering components for automatic sprinkler systems, and is included in a series of European Standards planned to cover a automatic sprinkler systems EN 12845 b gas systems EN 12094 c powder systems EN 124161; d explosion protection systems EN 26 184; e foam systems EN 135651; f hydrant and hose reel systems EN 671; g smoke and heat control systems EN 121011; h water spray systems EN ......1. EN 12259 has the general title, Fixed fire fighting systems – Components for sprinkler and water spray systems, and will consist of the following parts Part 1 Sprinklers; Part 2 Wet alarm valve assemblies; Part 3 Dry alarm valve assemblies; Part 4 Water motor alarms; Part 5 Water flow detectors; Part 6 Pipe couplings; 1 In preparation. Licensed Copy London South Bank University, London South Bank University, Thu Aug 10 125728 BST 2006, Uncontrolled Copy, c BSI Page 4 EN 12259-32000 BSI 2006 Part 7 Pipe hangers; Part 8 Pressure switches; Part 9 Deluge alarm valve assemblies; Part 10 Multiple controls; Part 11 Medium and high velocity water sprayers; Part 12 Pump sets. Anns A, B, C, D, E, F, G, H, I, J and K give test s and are normative. Annex L gives an example of a test schedule suitable for type approval of conventional designs and is inative. This standard is to be entrusted for use to qualified and experienced organizations which have a capability to design and manufacture to recognized international standards. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and the United Kingdom. Licensed Copy London South Bank University, London South Bank University, Thu Aug 10 125728 BST 2006, Uncontrolled Copy, c BSI Page 5 EN 12259-32000 BSI 2006 Foreword to amendment 1 This amendment EN 12259-32000/A12001 to the EN 12259-32000 has been prepared by Technical Committee CEN/TC 191, Fixed fire fighting systems, the Secretariat of which is held by BSI. This amendment to the European Standard EN 12259-32000 has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association, and supports essential requirements of EU Directives. For relationship with EU Directives, see inative annex ZA, which is an integral part of this standard. It s one part of EN 12259, covering components for automatic sprinkler systems and is included in a series of European Standards planned to cover automatic sprinkler systems EN 12259 gaseous extinguishing systems EN 120941; powder systems EN 124161; explosion protection systems EN 26184; foam systems EN 13565; hose reel systems EN 6711; smoke and heat control systems EN 121011; water spray systems1. EN 12259 has the general title, Fixed fire fighting systems Components for sprinkler and water spray systems, and will subdivided as follows Part 1 Sprinklers; Part 2 Wet alarm valve assemblies; Part 3 Dry alarm valve assemblies; Part 4 Water motor alarms; Part 5 Water flow detectors; Part 6 Pipe couplings; Part 7 Pipe hangers; Part 8 Pressure switches; Part 9 Deluge alarm valve assemblies; Part 10 Multiple controls; Part 11 Medium and high velocity water sprayers; Part 12 Sprinkler pump sets. Licensed Copy London South Bank University, London South Bank University, Thu Aug 10 125728 BST 2006, Uncontrolled Copy, c BSI Page 6 EN 12259-32000 BSI 2006 Foreword to amendment 2 This European Standard EN 12259-32000/A22005 has been prepared by Technical Committee CEN/TC 191 “Fixed firefighting systems”, the secretariat of which is held by BSI. This Amendment to the European Standard EN 12259-32000 shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by May 2006, and conflicting national standards shall be withdrawn at the latest by August 2007. This European Standard has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association, and supports essential requirements of EU Directives. For relationship with EU Directives, see inative Annex ZA, which is an integral part of this European Standard. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. Licensed Copy London South Bank University, London South Bank University, Thu Aug 10 125728 BST 2006, Uncontrolled Copy, c BSI Page 7 EN 12259-32000 BSI 2006 1 Scope This part of EN 12259 specifies requirements for construction and perance of dry alarm valve assemblies, accelerators and exhausters used in automatic sprinkler systems coning to anns A and B of prEN 12845, Automatic sprinkler systems – Design and installation. Auxiliary components and attachments to dry alarm valve assemblies, accelerators and exhausters are not covered by this standard. 2 Normative references This European Standard incorporates by dated or undated reference, provisions from other publications. These normative references are cited at the appropriate places in the text and the publications are listed hereafter. For dated references, subsequent amendments to or revisions of any of these publications apply to this European Standard only when incorporated in it by amendment or revision. For undated references the latest edition of the publication referred to applies. Reference deleted ISO 65 Carbon steel tubes suitable for screwing in accordance with ISO 7-1. Reference deleted ISO 868 Plastics and ebonite – Determination of indentation hardness by means of a dorometer shore hardness. ISO 898-1 Mechanical properties of fasteners – Part 1 Bolts, screws and studs. ISO 898-2 Mechanical properties of fasteners – Part 2 Nuts with specified proof load values. prEN 12845 Automatic sprinkler systems – Design and installation. Licensed Copy London South Bank University, London South Bank University, Thu Aug 10 125728 BST 2006, Uncontrolled Copy, c BSI Page 8 EN 12259-32000 BSI 2006 3 Definitions For the purposes of this standard the following definitions apply. 3.1 accelerator quick opening device see 3.18 to hasten the operation of a dry alarm valve using mechanical means other than by reducing the installation air/inert gas pressure, to the valve trip point 3.2 alarm device mechanical or electrical device to sound an alarm on operation of the dry alarm valve [EN 12259-21999] 3.3 anti-flooding device device to prevent excessive water from entering any relevant part or parts of the quick opening device see 3.18 where this might prevent subsequent operation 3.4 anti-reset latch mechanism to prevent the sealing assembly from returning to its closed position after operation 3.5 automatic drain valve normally ope