BS_EN_1993-3-2-2006_欧洲法规3.钢结构的设计.塔、杆和烟囱.烟囱.pdf
BRITISH STANDARD BS EN 1993-3-22006 Eurocode 3 Design of steel structures Part 3-2 Towers, masts and chimneys Chimneys ICS 91.010.30; 91.060.40; 91.080.10 --,,,,,,,,,,,,--,,,,,,,--- BS EN 1993-3-22006 This British Standard was published under the authority of the Standards Policy and Strategy Committee on 30 May 2008 BSI 2008 ISBN 978 0 580 54894 9 National foreword This British Standard is the UK implementation of EN 1993-3-22006. The structural Eurocodes are divided into packages by grouping Eurocodes for each of the main materials concrete, steel, composite concrete and steel, timber, masonry and aluminium; this is to enable a common date of withdrawal DOW for all the relevant parts that are needed for a particular design. The conflicting national standards will be withdrawn at the end of the coexistence period, after all the EN Eurocodes of a package are available. Following publication of the EN, there is a period allowed for national calibration during which the National Annex is issued, followed by a coexistence period of a maximum three years. During the coexistence period Member States are encouraged to adapt their national provisions. Conflicting national standards will be withdrawn by March 2010 at the latest. In the UK, the following national standard is partially superseded by BS EN 1993-3-22006. This standard will be withdrawn by March 2010 at the latest. Where a normative part of this EN allows for a choice to be made at the national level, the range and possible choice will be given in the normative text, and a note will qualify it as a Nationally Determined Parameter NDP. NDPs can be a specific value for a factor, a specific level or class, a particular or a particular application rule if several are proposed in the EN. To enable BS EN 1993-3-22006 to be used in the UK, the NDPs will be published in a National Annex, which will be made available by BSI in due course, after public consultation has taken place. The UK participation in its preparation was entrusted by Technical Committee B/525, Building and civil engineering structures, to Subcommittee B/525/32, Towers and masts and Subcommittee B/525/13, Chimneys. A list of organizations represented on this committee can be obtained on request to its secretary. This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. Compliance with a British Standard cannot confer immunity from legal obligations. British Standard partially superseded BS 40761989Specification for steel chimneys Amendments/corrigenda issued since publication DateComments --,,,,,,,,,,,,--,,,,,,,--- 标准分享网 w w w .b z f x w .c o m 免费下载 w w w . b z f x w . c o m EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 1993-3-2 October 2006 ICS 91.010.30; 91.060.40; 91.080.10Supersedes ENV 1993-3-21997 English Version Eurocode 3 - Design of steel structures - Part 3-2 Towers, masts and chimneys - Chimneys Eurocode 3 - Calcul des structures en acier - Partie 3-2 Tours, mts et chemines - Chemines Eurocode 3 - Bemessung und Konstruktion von Stahlbauten - Teil 3-2 Trme, Maste und Schornsteine - Schornsteine This European Standard was approved by CEN on 13 January 2006. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CEN member. This European Standard exists in three official versions English, French, German. A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the Central Secretariat has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre rue de Stassart, 36 B-1050 Brussels 2006 CENAll rights of exploitation in any and by any means reserved worldwide for CEN national Members. Ref. No. EN 1993-3-22006 E --,,,,,,,,,,,,--,,,,,,,--- w w w . b z f x w . c o m EN 1993-3-2 2006 E 2 Contents 1 General.......................................................................................................................................................5 1.1 Scope..................................................................................................................................................5 1.2 Normative references.........................................................................................................................6 1.3 Assumptions.......................................................................................................................................6 1.4 Distinction between principles and application rules.........................................................................6 1.5 Terms and definitions.........................................................................................................................6 1.6 Symbols used in Part 3.2 of Eurocode 3............................................................................................9 2 Basis of design............................................................................................................................................9 2.1 Requirements......................................................................................................................................9 2.2 Principles of limit state design.........................................................................................................10 2.3 Actions and environmental influences.............................................................................................10 2.4 Ultimate limit state verifications......................................................................................................12 2.5 Geometrical data..............................................................................................................................12 2.6 Durability.........................................................................................................................................12 3 Materials ..................................................................................................................................................12 3.1 General.............................................................................................................................................12 3.2 Structural steels................................................................................................................................12 3.3 Connections......................................................................................................................................12 4 Durability.................................................................................................................................................13 4.1 Allowance for corrosion...................................................................................................................13 4.2 External corrosion allowance...........................................................................................................13 4.3 Internal corrosion allowance............................................................................................................13 5 Structural analysis...................................................................................................................................14 5.1 Modelling of the chimney for determining action effects................................................................14 5.2 Calculation of internal stress resultants and stresses........................................................................14 6 Ultimate limit states.................................................................................................................................16 6.1 General.............................................................................................................................................16 6.2 Structural shells................................................................................................................................17 6.3 Safety assessment of other structural elements of the chimney.......................................................18 6.4 Joints and connections......................................................................................................................18 6.5 Welded connections.........................................................................................................................19 7 Serviceability limit states........................................................................................................................19 7.1 Basis.................................................................................................................................................19 7.2 Deflections.......................................................................................................................................19 8 Design assisted by testing........................................................................................................................20 9 Fatigue......................................................................................................................................................20 9.1 General.............................................................................................................................................20 9.2 Fatigue loading.................................................................................................................................21 9.3 High cycle fatigue resistances..........................................................................................................21 9.4 Safety assessment.............................................................................................................................21 9.5 Partial factors for fatigue..................................................................................................................22 Annex A [normative] – Reliability differentiation and partial factors for actions...................................23 A.1 Reliability differentiation for steel chimneys...................................................................................23 A.2 Partial factors for actions..................................................................................................................23 BS EN 1993-3-22006 --,,,,,,,,,,,,--,,,,,,,--- 标准分享网 w w w .b z f x w .c o m 免费下载 w w w . b z f x w . c o m EN 1993-3-2 2006 E 3 Annex B [inative] – Aerodynamic and damping measures................................................................24 B.1 General.............................................................................................................................................24 B.2 Aerodynamic measures....................................................................................................................24 B.3 Dynamic vibration absorber.............................................................................................................25 B.4 Cables with damping devices...........................................................................................................25 B.5 Direct damping.................................................................................................................................25 Annex C [inative] – Fatigue resistances and quality requirements...................................................26 C.1 General.............................................................................................................................................26 C.2 Enhancement of fatigue strength for special quality requirements..................................................26 Annex D [inative] – Design assisted by testing ....................................................................................29 D.1 General.............................................................................................................................................29 D.2 Definition of the logarithmic damping decrement...........................................................................29 D.3 Procedure for measuring the logarithmic damping decrement.........................................................29 Annex E [inative] – cution...............................................................................................................30 E.1 General.............................................................................................................................................30 E.2 cution tolerances ........................................................................................................................30 E.3 Quality of welds and fatigue............................................................................................................30 BS EN 1993-3-22006 --,,,,,,,,,,,,--,,,,,,,--- w w w . b z f x w . c o m EN 1993-3-2 2006 E 4 Foreword This European Standard EN 1993-3-2, Eurocode 3 Design of steel structures Part 3-2 Towers, masts and chimneys – Chimneys, has been prepared by Technical Committee CEN/TC250 Structural Eurocodes , the Secretariat of which is held by BSI. CEN/TC250 is responsible for all Structural Eurocodes. This European Standard shall be given the status of a National Standard, either by publication of an identical text or by endorsement, at the latest by April 2007 and conflicting National Standards shall be withdrawn at latest by March 2010. This Eurocode supersedes ENV 1993-3-2. According to the CEN-CENELEC Internal Regulations, the National Standard Organizations of the following countries are bound to implement this European Standard Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerl